CPCBIV+ COMPLIANT

INDIA’S LARGEST FLEET OF GENSETS   |   320 - 750 kVA

Enquire Now

A RICH HERITAGE OF OVER A CENTURY OF ENGINEERING EXCELLENCE.

Kirloskar Genset

Kirloskar power generating sets prioritize user experience, delivering exceptional features and benefits. Streamlined installation and enhanced dependability to expedited service, reduced maintenance costs, and optimized performance.

Kirloskar Powergen sets itself apart with groundbreaking engineering that establishes new industry benchmarks.

LIMITLESS POTENTIAL, SUSTAINABLE PRACTICES

Our state-of-the-art manufacturing facility embodies our commitment to sustainable practices. We partner with nature to power the facility itself, transforming waste into valuable resources. This focus on sustainability inspires both our workforce and surrounding communities. It's here, where cutting-edge technology meets exceptional skills, that we engineer solutions to empower limitless possibilities.

320 - 750 kVA TECHNICAL SPECIFICATIONS

Prime Rating at rated rpm (as per ISO8528) kVA 320 400 500 625 750
kW 256 320 400 500 600
Genset Model KG4-320WS1 KG4-400WS11 KG4-500WS KG4-625WS KG4-750WS
Frequency Hz 50
Power Factor lagging 0.8
Voltage V 415 (3Ø)
Governing class (As per ISO 8528 Part-V) G3
DG set Noise level at 1 meter dBA <75 (Genset with canopy)
Fuel tank capacity (Standard DG set) Ltrs 600 850 850 990 990
✪ Weight of genset with canopy (approx..)^ Dry Kg 4090 6220 6240 8150 8760
Wet (w/o fuel) Kg 4200 6415 6435 8370 9100
Overall dimensions of genset ^ Length mm 4750 5575 5575 6500 6800
Width mm 1700 2125 2125 2125 2300
Height mm 2005 2610 2610 2710 2715
Electrical Battery Starting Voltage Volts-DC 24
ENGINE
Engine Model 6SL90ETA 4G3 DV8ETA 4G2 DV8ETA 4G3 DV10ETA 4G2 DV12ETA 4G2
Rated output (Prime Continuous rating as per ISO 8528-1) kW 279.5 360 447.2 561.1 662
HP 380 490 608 763 900.6
No. of cylinder Number 6 8 8 10 12
Cubic capacity Ltrs 8.86 15.92 15.92 19.9 23.88
Bore x Stroke mm 118 x 135 130 x 150 130 x 150 130 x 150 130 x 150
Rated Speed RPM 1500
Aspiration NA/TC/TA TA
Lube Oil change period hrs. 500
Lube oil Sump Capacity Ltrs 27 40 40 50 73
Coolant Capacity (Engine + Radiator) Ltrs 36 63.2 63.2 81.7 173.9
Adblue/DEF capacity Ltrs 45 45 x 2 45 x 2 45 x 2 45 x 2
ALTERNATOR
Insulation Class Class H
Alternator Efficiency (at 100% load) 0.8 pf** % 95.3 93.4 94.8 95.7 94.7
Max Voltage Dip at Full Load 0.8 pf lag < 20 %
Max Time to build up rated voltage at Rated RPM < 2 sec, provided engine reach the rated speed

^ Tolerances Apply

✪ These Weight are for handling & transportation only

**Efficiency of Alternator as per standards IEC60034-1

Notes

AdBlue used should follow ISO 22241.

Above specifications are subject to change without prior notice due to continuous technical development.

For intermediate ratings, kindly contact nearest Kirloskar office.

For Site Conditions other than standard operating conditions consult Kirloskar Oil Engines for available prime power.

7 Easy steps for a happy Genset Ownership

Genset kVA Features 320 to 750 kVA Features


Prime rating and Stand-by rating

‘Prime power’ is designed for Unlimited hours, as compared to 'Emergency stand-by' designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rating to meet their requirement. Kirloskar offers Prime power as a standard offer. Contact Kirloskar for stand-by ratings.

Best-in-class Fluid Efficiency (Fuel & DEF)

Kirloskar Gensets offer a unique combination of CPCB norm compliance and enhanced fuel efficiency. Across the range, Kirloskar Gensets offer substantial savings in fuel cost.

O2E Series (Optimal Operating Efficiency):

Genset ratings are selected based on the present load and future expansion. Fuel efficiency of most Gensets is optimized at the full rating of the Genset.

In practice, Gensets rarely get loaded to full capacity. Power demand variations across day & night, weekdays & weekends, summer & winter lead to an average 50-70% loading on Gensets.

Considering this practical situation, Kirloskar has extended fuel efficiency optimization from 100%, right up to 50% of rated load.

In line with fuel efficiency Kirloskar Genset ensures the better DEF efficiency and accordingly optimized the DEF tank size.

Combination of best-in-class fuel efficiency & O2E provides a double advantage.

No replacement to displacement

Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.

Higher engine capacity also enables the Genset to respond quickly & positively to sudden load additions.

Common Rail Direct Injection System (CRDi):

Common rail diesel injection technology, popularly known as CRDi, provides a significant upgrade over traditional mechanical fuel injection systems. CRDi provides precise fuel control, multiple injections, enhanced performance, lower noise and reduced emissions. High pressure common rail system employed on Kirloskar CPCB IV+ Gensets maximizes fuel atomization, delivering a smooth and smoke free performance. Diesel filters with ‘A’ class filtration are used for CRDi Engines which enhances the filtration efficiency. Common rail fuel injection system will provide a new level of performance, efficiency, and reliability.

Genset Monitoring at Your Finger Tips

Kirloskar gensets are enabled with Kirloskar remote monitoring system which shares Real Time Genset information and location Services. It can be accessed via mobile device or desktop. Kirloskar remote monitoring system also highlights any parameter which needs special attention. These critical indication alerts are sent to user mobile via text message. It also alerts nearest services dealer in case of any emergency break-down.

State of the art Genset Controller

Kirloskar Genset put the command in your hands. Micro-processor based Genset controllers display a host of genset parameters and put all controls at your fingertips.

Monitoring Features:

Diagnostic Features:

Optional Features:

Peace-of-mind Ownership

Kirloskar Gensets have always been preferred for their robust design and reliability over long usage life. Kirloskar range carries the confidence of well-established and proven engine platforms. For compliance to revised CPCB norms, Kirloskar has carefully selected those technologies which not only retain, but enhance Gensets durability and on-site serviceability.

Thus, Kirloskar Gensets offer you many years of trouble-free performance; backed by the assurance of prompt support. Peace-of-mind driven by product reliability and low cost of ownership.

On Board Diagnostics

Superior uptime. Genset comes with advanced diagnostic capabilities, this coupled with Kirloskar remote monitoring system provides real time monitoring of performance, emission and service critical parameters this helps for early diagnosis to fix the issues before system breakdown.

Alternator Features

Kirloskar Alternator is compact in design & comes with AREP winding and Digital AVR. Auxillary Regulation Excitation Principle (AREP) winding improves the Non-linear load handling capability, Motor starting capacity. Advanced Digital AVR improves the Voltage regulation and Response time.

Compact footprint

Kirloskar CPCB compliant Gensets are having compact footprint which results in space saving. CPCB compliant technology is upgraded by maintaining the compact footprint of Genset.

Glimpses CPCB IV+ Genset (320-750 kVA)


  • Engine
    • Efficient CRDi System
    • O2E Series: Low emission, high efficiency engines
    • Compact, Robust and Rugged Design
    • 500 hours lube-oil change period
    • Integral set - mounted radiator system, designed & tested for 50°C ambient temperature
  • Controller
    • Microprocessor based
    • Graphical LCD display
    • Best in class monitoring and diagnostic capability
    • Integrable with AMF, synchronization (optional) & communication compatible
  • Supply Module & DCU
    • Control & monitor the DEF
  • Exhaust Gas Treatment System
    • DOC & SCR system sets off the reaction to meet the latest CPCB norms
    • Reduction in NOx & HC
    • Reduction in PM
  • DEF Tank
    • DEF/Aqueous urea to sets off the chemical reaction with Exhaust gas
    • Tank size is optimized in accordance to DEF consumption
  • O2E - Optimal operating efficiency
  • DEF - Diesel exhaust fluid
  • DCU - Dosing control unit
  • DOC - Diesel oxidation catalyst